Linux ip-172-26-7-228 5.4.0-1103-aws #111~18.04.1-Ubuntu SMP Tue May 23 20:04:10 UTC 2023 x86_64
Your IP : 18.117.11.13
# Copyright (C) 2011 Canonical Ltd.
#
# Author: Scott Moser <scott.moser@canonical.com>
#
# This file is part of cloud-init. See LICENSE file for license information.
"""Power State Change: Change power state"""
import errno
import logging
import os
import re
import subprocess
import time
from cloudinit import subp, util
from cloudinit.cloud import Cloud
from cloudinit.config import Config
from cloudinit.config.schema import MetaSchema
from cloudinit.distros import ALL_DISTROS
from cloudinit.settings import PER_INSTANCE
frequency = PER_INSTANCE
EXIT_FAIL = 254
meta: MetaSchema = {
"id": "cc_power_state_change",
"distros": [ALL_DISTROS],
"frequency": PER_INSTANCE,
"activate_by_schema_keys": ["power_state"],
} # type: ignore
LOG = logging.getLogger(__name__)
def givecmdline(pid):
# Returns the cmdline for the given process id. In Linux we can use procfs
# for this but on BSD there is /usr/bin/procstat.
try:
# Example output from procstat -c 1
# PID COMM ARGS
# 1 init /bin/init --
if util.is_FreeBSD():
(output, _err) = subp.subp(["procstat", "-c", str(pid)])
line = output.splitlines()[1]
m = re.search(r"\d+ (\w|\.|-)+\s+(/\w.+)", line)
return m.group(2)
else:
return util.load_text_file("/proc/%s/cmdline" % pid)
except IOError:
return None
def check_condition(cond):
if isinstance(cond, bool):
LOG.debug("Static Condition: %s", cond)
return cond
pre = "check_condition command (%s): " % cond
try:
proc = subprocess.Popen(cond, shell=not isinstance(cond, list))
proc.communicate()
ret = proc.returncode
if ret == 0:
LOG.debug("%sexited 0. condition met.", pre)
return True
elif ret == 1:
LOG.debug("%sexited 1. condition not met.", pre)
return False
else:
LOG.warning("%sunexpected exit %s. do not apply change.", pre, ret)
return False
except Exception as e:
LOG.warning("%sUnexpected error: %s", pre, e)
return False
def handle(name: str, cfg: Config, cloud: Cloud, args: list) -> None:
try:
(arg_list, timeout, condition) = load_power_state(cfg, cloud.distro)
if arg_list is None:
LOG.debug("no power_state provided. doing nothing")
return
except Exception as e:
LOG.warning("%s Not performing power state change!", str(e))
return
if condition is False:
LOG.debug("Condition was false. Will not perform state change.")
return
mypid = os.getpid()
cmdline = givecmdline(mypid)
if not cmdline:
LOG.warning("power_state: failed to get cmdline of current process")
return
devnull_fp = open(os.devnull, "w")
LOG.debug("After pid %s ends, will execute: %s", mypid, " ".join(arg_list))
util.fork_cb(
run_after_pid_gone,
mypid,
cmdline,
timeout,
condition,
execmd,
[arg_list, devnull_fp],
)
def load_power_state(cfg, distro):
# returns a tuple of shutdown_command, timeout
# shutdown_command is None if no config found
pstate = cfg.get("power_state")
if pstate is None:
return (None, None, None)
if not isinstance(pstate, dict):
raise TypeError("power_state is not a dict.")
modes_ok = ["halt", "poweroff", "reboot"]
mode = pstate.get("mode")
if mode not in distro.shutdown_options_map:
raise TypeError(
"power_state[mode] required, must be one of: %s. found: '%s'."
% (",".join(modes_ok), mode)
)
args = distro.shutdown_command(
mode=mode,
delay=pstate.get("delay", "now"),
message=pstate.get("message"),
)
try:
timeout = float(pstate.get("timeout", 30.0))
except ValueError as e:
raise ValueError(
"failed to convert timeout '%s' to float." % pstate["timeout"]
) from e
condition = pstate.get("condition", True)
if not isinstance(condition, (str, list, bool)):
raise TypeError("condition type %s invalid. must be list, bool, str")
return (args, timeout, condition)
def doexit(sysexit):
os._exit(sysexit)
def execmd(exe_args, output=None, data_in=None):
ret = 1
try:
proc = subprocess.Popen( # nosec B603
exe_args,
stdin=subprocess.PIPE,
stdout=output,
stderr=subprocess.STDOUT,
)
proc.communicate(data_in)
ret = proc.returncode
except Exception:
doexit(EXIT_FAIL)
doexit(ret)
def run_after_pid_gone(pid, pidcmdline, timeout, condition, func, args):
# wait until pid, with /proc/pid/cmdline contents of pidcmdline
# is no longer alive. After it is gone, or timeout has passed
# execute func(args)
msg = None
end_time = time.monotonic() + timeout
def fatal(msg):
LOG.warning(msg)
doexit(EXIT_FAIL)
known_errnos = (errno.ENOENT, errno.ESRCH)
while True:
if time.monotonic() > end_time:
msg = "timeout reached before %s ended" % pid
break
try:
cmdline = givecmdline(pid)
if cmdline != pidcmdline:
msg = "cmdline changed for %s [now: %s]" % (pid, cmdline)
break
except IOError as ioerr:
if ioerr.errno in known_errnos:
msg = "pidfile gone [%d]" % ioerr.errno
else:
fatal("IOError during wait: %s" % ioerr)
break
except Exception as e:
fatal("Unexpected Exception: %s" % e)
time.sleep(0.25)
if not msg:
fatal("Unexpected error in run_after_pid_gone")
LOG.debug(msg)
try:
if not check_condition(condition):
return
except Exception as e:
fatal("Unexpected Exception when checking condition: %s" % e)
func(*args)
|